Structured Cable Products RG6/UQ-BC-WT-SPL RG6/U Quad-Shield 3Ghz Coaxial Cable 1000' Spool - White
- RG6/U quad-shield coaxial cable
- Performance rated up to 3.0 GHz
- 1,000 ft. (305 m) spool
- White Jacket
Overview
The SCP RG6/UQ-BC-XX-SPL is a 75-ohm RG6/U quad-shield coaxial cable featuring an 18 AWG bare copper center conductor and performance sweep tested to 3.0 GHz. Its quad-shield construction combines two 100% aluminum foil shields with 60% and 40% aluminum braid layers for enhanced shielding performance. The cable features a flame-retardant PVC jacket, CM rating, and is supplied on a 1,000-foot spool for professional low-voltage installations.
Features
- RG6/U quad-shield coaxial cable
- Sweep tested to 3.0 GHz
- 18 AWG solid bare copper center conductor
- 75 ±3 ohm impedance
- Skin foam polyethylene dielectric
- First bonded aluminum foil shield with 100% coverage
- First aluminum braid shield with 60% coverage
- Second aluminum foil shield with 100% coverage
- Second aluminum braid shield with 40% coverage
- 85% velocity of propagation
- 16.2 pF/ft capacitance
- 6.55 ohms/kft conductor DC resistance at 20°C
- 12.75 ohms/kft DC loop resistance at 20°C
- Minimum structural return loss of 20 dB from 5 to 1000 MHz
- Minimum structural return loss of 15 dB from 1001 to 3000 MHz
- Flame-retardant PVC jacket
- CM rated
- Overall cable diameter of 0.297 in. (7.54 mm)
- Operating temperature range of -20°C to 75°C
- Cold bend tested at -20°C with no cracking
- UL, CE, and RoHS compliant
- Available with black or white jacket
- 1,000 ft. (305 m) spool
Specifications
| Product Information | |||||
|---|---|---|---|---|---|
| Black Model | RG6/UQ-BC-BK-SPL | ||||
| Black Description | RG6/U QUAD SHIELD 3.0 GHz 18 AWG BC, 60%/40% AL BRAID, CM RATING - 1000 FT SPOOL- BLACK | ||||
| White Model | RG6/UQ-BC-WT-SPL | ||||
| White Description | RG6/U QUAD SHIELD 3.0 GHz 18 AWG BC, 60%/40% AL BRAID- 1000 FT SPOOL- WHITE | ||||
| Construction | |||||
| Center Conductor | Bare Copper | ||||
| Size | 18AWG | ||||
| Center Conductor Diameter (in/mm) | 0.0403/1.02 | ||||
| Insulate | Skin Foam PE | ||||
| Nom. Insulation Thickness (in/mm) | 0.070/1.78 | ||||
| Insulation Diameter (in/mm) | 0.0180/4.57 | ||||
| The First Shield | Bonded Aluminum Foil | ||||
| First Shield Coverage Area | 100% | ||||
| The First Braid Shield | Aluminum Wire | ||||
| First Braid Shield Coverage Area | 60% | ||||
| The Second Shield | Aluminum Foil | ||||
| Second Shield Coverage Area | 100% | ||||
| The Second Braid Shield | Aluminum Wire | ||||
| Second Braid Shield Coverage Area | 40% | ||||
| Black Jacket | Black FR-PVC | ||||
| White Jacket | White FR-PVC | ||||
| Nom. Jacket Thickness (in/mm) | 0.030/0.76 | ||||
| Min. Jacket Thickness (in/mm) | 0.024/0.61 | ||||
| Cable Diameter (in/mm) | 0.297/7.54 | ||||
| Electrical Characteristics | |||||
| Test Temperature | 68°F (20°C) | ||||
| Dielectric Strength | 1 kV/min | ||||
| Impedence | 75±3.0 ohms | ||||
| SRL - 5~1000MHz | >=20 dB | ||||
| SRL - 1001~3000MHz | >=15 dB | ||||
| Capacitance | 16.2 pF/ft | ||||
| Conductor DCR @ 20°C | 6.55 ohms/kft | ||||
| DC Loop Resistance @ 20°C | 12.75 ohms/kft | ||||
| Velocity Of Propagation | 85% | ||||
| Attenuation | |||||
| Frequency (MHz) | Attenuation (dB/100ft) | Attenuation (dB/100m) | |||
| 5 | 0.52 | 1.70 | |||
| 10 | 0.72 | 2.33 | |||
| 50 | 1.47 | 4.79 | |||
| 100 | 2.05 | 6.72 | |||
| 200 | 2.84 | 9.28 | |||
| 400 | 4.06 | 13.28 | |||
| 700 | 5.60 | 18.36 | |||
| 900 | 6.24 | 20.43 | |||
| 1000 | 6.60 | 21.61 | |||
| 1200 | 7.50 | 24.59 | |||
| 1450 | 8.04 | 26.36 | |||
| 1800 | 8.84 | 28.98 | |||
| 2200 | 9.77 | 32.03 | |||
| 2500 | 11.13 | 36.47 | |||
| 2750 | 11.58 | 37.94 | |||
| 3000 | 12.06 | 39.54 | |||
| Mechanical Characteristics | |||||
| Test Object | Jacket | ||||
| Before Aging - Tensile Strength | 2000 psi | ||||
| Before Aging - Elongation | 200% | ||||
| Aging Condition | 100°C / 168 hrs | ||||
| After Aging - Tensile Strength | >=85% unaged | ||||
| After Aging - Elongation | >=50% unaged | ||||
| Cold Bend | No Crack (-20±2°C / 4 hrs) | ||||
| Jacket Longitudinal Shrinkage | >=5% | ||||
| Center Conductor Break Strength | 85 lbs | ||||
| Operating Temperature Range | -20~75°C | ||||
| Packing | |||||
| Package | Spool | ||||
| Length | 1000 ft / 305 m | ||||
| Gross Weight | 35.05 lbs / 15.9 kg | ||||
| Standards | |||||
| Standards | UL, CE, RoHS | ||||
| Marking | |||||
| Jacket Marking | STRUCTURED CABLE PRODUCTS Exxxxxx (UL) OR C(UL) CM 18 AWG BC 75C MM/YY -- P/N: RG6/UQ-BC -- RG6/U QUAD SHIELD SWEEP TESTED TO 3.0 GHz HDTV, 60%/40% AL BRAID CE EU RoHS EC ZONE/DEVICE A B C D E 0 1 2 3 4 5 6 7 8 9 xxxxFEET | ||||
| Revision | REV.A | ||||
| Rev Date | 05/2013 | ||||