Lutron RRST-ANF-WH Sunnata RF Touch 4-Speed Quiet Fan Control - White
- RadioRA 3 Sunnata Local Controls
- Fan Control Paddle Switch
- Requires a wallbox 2.5" (64 mm) deep minimum
Overview
Lutron RadioRA 3 SUNNATA RF Touch 4-Speed Quiet Fan Control
With the Sunnata RF Touch 4-Speed Quiet Fan Control, easily turn on the fan to the ideal speed by tapping the paddle switch or touching anywhere on the light bar.
Features
- Touch or swipe the light bar to set your fan to the right speed
- Four quiet speeds for increased comfort
- Soft glow helps the homeowner find the switch in the dark
- Light bar brightness can be customized, including off if preferred in places like the bedroom
- Installs in as little as 15 minutes; neutral wire required
- Capable of controlling one paddle-type ceiling fan, up to 1.5A
Specifications
| General Specifications | |||||
| Model | RRST-ANF-WH | ||||
| Product Name | RadioRA 3 RF Sunnata Local Controls | ||||
| Control Type | Fan Control | ||||
| Model / Orderable SKU | RRST-ANF-WH | ||||
| Manufacturer Family | RadioRA 3 Sunnata local controls | ||||
| Application | Single pole only for fan control | ||||
| Supported Load | One (1) paddle-type AC ceiling fan only | ||||
| AC/DC Compatibility | AC fan only; not for DC motor fans | ||||
| Compatible Finishes | White, Ivory, Light Almond, Black and multiple satin finishes; supplied SKU corresponds to White (WH) | ||||
| Electrical | |||||
|---|---|---|---|---|---|
| Input Voltage | 120 V~ | ||||
| Line Frequency | 50/60 Hz | ||||
| Maximum Current | 1.5 A max. | ||||
| Minimum Load | 0.08 A | ||||
| Load Rating at Not Ganged | 1.5 A | ||||
| Load Rating at End of Gang | 1.5 A | ||||
| Load Rating at Middle of Gang | 1.5 A | ||||
| Neutral Connection | Required | ||||
| Typical Power Consumption | 0.5 W | ||||
| Operating Features | |||||
| Fan Speed Selection | Four speeds: High, Medium-High, Medium and Low | ||||
| On Operation | Pressing ON sets the fan to the previous speed; double-tap goes to high/maximum speed | ||||
| Off Operation | Press and hold OFF for more than 1 second for delayed off (30 second delay) | ||||
| Locator / Light Bar | Includes light bar; brightness and locator light are adjustable via MyLevel | ||||
| Front Accessible Service Switch (FASS) | Included for service/cleaning and power isolation | ||||
| Wiring and Installation | |||||
| Installation Type | Single-pole installation | ||||
| Wallbox Requirement | Requires a U.S. wallbox; 2.5 in (63.5 mm) minimum depth for RRST-ANF | ||||
| Recommended Wallbox Depth | 3½ in (89 mm) deep recommended | ||||
| Ground Connection | Ground required per wiring diagram | ||||
| Neutral Wire Requirement | Neutral required for all load types | ||||
| Physical | |||||
| Dimensions H x W | 4 11/16 in (119 mm) x 2 15/16 in (75 mm) | ||||
| Control Depth from Wall | 1 9/16 in (39 mm) | ||||
| Projecting Depth / Overall Depth on Drawing | 2 9/16 in (65 mm) | ||||
| Device Thickness | 5/16 in (8 mm) | ||||
| Wallplate | Wallplate adapter and wallplate sold separately | ||||
| Environmental and Compliance | |||||
| Operating Temperature | 32 °F to 104 °F (0 °C to 40 °C) | ||||
| Operating Humidity | 0% to 90% humidity, non-condensing | ||||
| Indoor Use | Indoor use only | ||||
| Communications | Clear Connect-Type X RF; 2.4 GHz system frequency | ||||
| Regulatory Approvals | cULus, NOM, FCC, IC, IFT | ||||
| ESD Protection | Tested to withstand electrostatic discharge without damage or memory loss per IEC 61000-4-2 | ||||
| Surge Protection | Tested to withstand surge voltages without damage or loss of operation per IEEE C62.41-1991 | ||||
| Power Failure Memory | Returns to previous state when power is restored | ||||