Lutron RRST-8ANS-SW RadioRA 3 Sunnata RF Switch - Snow
- RadioRA 3 Sunnata Switch
- Controls up to 8A Lighting or 5.5A (1/4 HP) Motor Loads
- Locator light
- Coordinates with Full Sunnata Family
Overview
RadioRA 3 Sunnata local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single circuits of lighting need to be dimmed or switched.
RadioRA 3 Sunnata local controls include a locator light to assist in locating the controls at night. RadioRA 3 Sunnata local controls install in single pole or multi-location applications. Sunnata companion dimmers and companion switches must be used for multi-location control. RadioRA 3 Sunnata local controls include a Front Accessible Service Switch (FASS) for safe light bulb replacement.
Features
- For non-dim applications including lighting and small motor loads
- Controls up to 8A lighting or 5.5A (1/4 HP) motor loads
- Locator light glows softly to find switch in the dark
- Works with up to 4 companions for 5-location control
- Press and hold for 30-second delayed fade-to-off
- Coordinates with full Sunnata family for unified style
- Pressing the top of the button, lights or motors turn ON.
- Pressing the bottom of the button, lights or motors turn OFF.
- Neutral is required. (Switch only)
- Pressing and holding the bottom of the button for more than 1 second - Delayed Off (30 second delay)
- Single pole or multi-location control
- Use Lutron Designer (Claro gloss or satin finish) wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately
- 120 V~ 50/60 Hz
- Lighting Load – 8 A
- Motor Load – 1/4 HP 5.8 A
Non-RF Switch ST-6ANS-(XX)
Non-RF Companion Switch ST-RS-(XX)
Specifications
| General Specifications | |||||
| Model | RRST-8ANS-SW | ||||
| Vendor | Lutron | ||||
| Wallplate | Sold separately | ||||
| FASS Service Switch | Included | ||||
| Control Type | Neutral-wire electronic switch | ||||
| Neutral Connection | Required | ||||
| Recording and Storage | |||||
|---|---|---|---|---|---|
| Power-Failure Memory | Returns to previous state when power is restored | ||||
| Connections and Communications | |||||
| Companion Wiring | Up to four matching companions; 150 feet total wire length maximum | ||||
| RF Technology | Clear Connect Type X, 2.4 GHz | ||||
| RF Placement | Within 75 feet of centrally located processor; follow Type X network placement rules | ||||
| Power and Electrical | |||||
| Power | 120 VAC, 50/60Hz | ||||
| Lighting Load | 8A maximum | ||||
| Motor Load | 1/4 HP, 5.8A maximum | ||||
| Typical Standby Power | 0.5W, load off and locator light enabled | ||||
| Physical Specifications | |||||
| Finish Code | SW | ||||
| Wallbox Depth | 3.5 inches recommended; 2.25 inches minimum | ||||
| Environmental Specifications | |||||
| Operating Temperature | 32°F to 104°F (0°C to 40°C) | ||||
| Humidity | 0-90%, non-condensing; indoor only | ||||